Temperature Humidity chamber
Descripition
Temperature huminity controlled chamber, also known as "programmable constant temperature and humidity test chamber constant temperature and humidity test chamber", and "high and low temperature alternating humidity and heat test chamber/GDS-100" belong to the same series, is a necessary test equipment in aviation, automobile, household appliances, scientific research and other fields, used to test and determine the electrical, electronic and other products and materials for high temperature. The parameters and performance of temperature, environment, temperature, temperature, humidity, heat or constant test.
Product Type Distinction
Constant temperature and humidity test box [2] can be divided into "desktop" and "vertical", the main difference is that the temperature and humidity can be achieved by different, resulting in different temperatures, vertical can do below normal temperature of low temperature and drying, desktop can only do above normal temperature and high humidity.
Corresponding Standard
1. Technical specification for GB11158 high temperature test chamber
2. Technical specification for GB10589-89 cryogenic test chamber
3. Technical specification for GB10592-89 high and low temperature test chamber
4. Technical specification for GB/T10586-89 hygrothermal chamber
5. GB/T2423.1-2008 low temperature test chamber test method
6. Test method for GB/T2423.2-2008 high temperature test chamber
7. Test method for GB/T2423.3-2006 hygrothermal chamber
8. GB/T2423.4-2008 test method for alternating humidity and heat
9. GB/T2423.22-2002 temperature change test method
10. IEC60068-2-1.1990 low temperature test chamber test method
11. Test method for IEC60068-2-2.1974 high temperature test chamber
12. GJB150.3 high temperature test
13. GJB150.4 low temperature test
14. GJB150.9 hygrothermal test
Production Specification
Model | IZ-80(A~F) | IZ-150(A~F) | IZ-225(A~F) | IZ-408(A~F) | IZ-800(A~F) | IZ-1000(A~F) |
Inner size: W×H×D(mm) | 40*50*40 | 50*60*50 | 60*75*50 | 60*85*80 | 100*100*80 | 100*100*100 |
External size W×H×D(cm) | 105*165*98 | 105*175*108 | 115*190*108 | 135*200*115 | 155*215*135 | 155*215*155 |
Temperature range | (low:A:+25ºC; B:0ºC;C:-20ºC; D:-40ºC;E:-60ºC;F:-70ºC) ( high :+100ºC/+150ºC) | |||||
Temp analytic accuracy/uniformity | 0.1ºC/±2.0ºC | |||||
Temperature control accuracy | ±0.5ºC | |||||
Heat; cooling time | Heat up about 4.0°C/min ; Cooling about 1.0°C/min | |||||
Inner and outer materials | SUS#304 Stainless steel for inner chamber ; Carton Advanced cold plate nano paint for outer | |||||
Heat insulation material | Resistant to high temp ,high density,formate chlorine,ethyl acetum foam insulation materials | |||||
Cooling system | Air cooling/single segment compressor(-40°C) ,air and water double segment compressor (-50°C~-70°C) | |||||
Protection devices | Fuse switch, compressor overload switch, refrigerant high and low pressure protection switch, super humidity over-temperature protection switch, fuse, failure warning system | |||||
Parts | Watching window , 50mm testing hole , PL internal bulbs , Wet and dry bulb gauze , partition plate , castorx4,Foot Cupx4 | |||||
Compressor | Original France"Tecumseh"brand | |||||
Controller | TEMI South Korea | |||||
Power | AC220V50/60Hz&1,AC380V 50/60Hz3 | |||||
weight (kg) | 150 | 220 | 270 | 320 | 450 | 580 |
Temperature Humidity chamber
Descripition
Temperature huminity controlled chamber, also known as "programmable constant temperature and humidity test chamber constant temperature and humidity test chamber", and "high and low temperature alternating humidity and heat test chamber/GDS-100" belong to the same series, is a necessary test equipment in aviation, automobile, household appliances, scientific research and other fields, used to test and determine the electrical, electronic and other products and materials for high temperature. The parameters and performance of temperature, environment, temperature, temperature, humidity, heat or constant test.
Product Type Distinction
Constant temperature and humidity test box [2] can be divided into "desktop" and "vertical", the main difference is that the temperature and humidity can be achieved by different, resulting in different temperatures, vertical can do below normal temperature of low temperature and drying, desktop can only do above normal temperature and high humidity.
Corresponding Standard
1. Technical specification for GB11158 high temperature test chamber
2. Technical specification for GB10589-89 cryogenic test chamber
3. Technical specification for GB10592-89 high and low temperature test chamber
4. Technical specification for GB/T10586-89 hygrothermal chamber
5. GB/T2423.1-2008 low temperature test chamber test method
6. Test method for GB/T2423.2-2008 high temperature test chamber
7. Test method for GB/T2423.3-2006 hygrothermal chamber
8. GB/T2423.4-2008 test method for alternating humidity and heat
9. GB/T2423.22-2002 temperature change test method
10. IEC60068-2-1.1990 low temperature test chamber test method
11. Test method for IEC60068-2-2.1974 high temperature test chamber
12. GJB150.3 high temperature test
13. GJB150.4 low temperature test
14. GJB150.9 hygrothermal test
Production Specification
Model | IZ-80(A~F) | IZ-150(A~F) | IZ-225(A~F) | IZ-408(A~F) | IZ-800(A~F) | IZ-1000(A~F) |
Inner size: W×H×D(mm) | 40*50*40 | 50*60*50 | 60*75*50 | 60*85*80 | 100*100*80 | 100*100*100 |
External size W×H×D(cm) | 105*165*98 | 105*175*108 | 115*190*108 | 135*200*115 | 155*215*135 | 155*215*155 |
Temperature range | (low:A:+25ºC; B:0ºC;C:-20ºC; D:-40ºC;E:-60ºC;F:-70ºC) ( high :+100ºC/+150ºC) | |||||
Temp analytic accuracy/uniformity | 0.1ºC/±2.0ºC | |||||
Temperature control accuracy | ±0.5ºC | |||||
Heat; cooling time | Heat up about 4.0°C/min ; Cooling about 1.0°C/min | |||||
Inner and outer materials | SUS#304 Stainless steel for inner chamber ; Carton Advanced cold plate nano paint for outer | |||||
Heat insulation material | Resistant to high temp ,high density,formate chlorine,ethyl acetum foam insulation materials | |||||
Cooling system | Air cooling/single segment compressor(-40°C) ,air and water double segment compressor (-50°C~-70°C) | |||||
Protection devices | Fuse switch, compressor overload switch, refrigerant high and low pressure protection switch, super humidity over-temperature protection switch, fuse, failure warning system | |||||
Parts | Watching window , 50mm testing hole , PL internal bulbs , Wet and dry bulb gauze , partition plate , castorx4,Foot Cupx4 | |||||
Compressor | Original France"Tecumseh"brand | |||||
Controller | TEMI South Korea | |||||
Power | AC220V50/60Hz&1,AC380V 50/60Hz3 | |||||
weight (kg) | 150 | 220 | 270 | 320 | 450 | 580 |