Melt Flow Index Tester
Description:
Melt flow index tester for ABS, polystyrene, polyethylene, polypropylene, polyamide, fiber resin, acrylate, POM, fluoroplastic, polycarbonate and other plastic materials, melt flow rate (MFR) or Melt volume flow (MVR) is to be determined.
Standards:
GB/T3682-2000,ISO1133-97, ASTM1238,ASTM D 3364,DIN 53735,UNI-5640,JJB878 ect.
Characteristics:
1. Fast heating speed, very small overshoot.
2. High precision of constant temperature.
3. Can accelerate recover to constant temperature condition after padding.
4. Can use manual and automatic material trimming test method.
5. LCD display, equipment with built-in micro printer, test result can be printed autocratically.
Specification:
Machine size(W*H*D) | 250*510*350mm |
Power | AC220V±10% 50/60HZ |
Barrel parameters | Inner hole 9.55±0.025mm |
Pistons parameters | Piston head: 9.475±0.015mm |
Piston length | H=6.35±0.1mm |
Paramters | Extrusion hole 1=2.095±0.005mm |
Temperature parameter | With intelligent temperature control instrument, with four pairs of significant temperature setting control, PID parameters can be automatically set, precision up to ± 0.1 degree centigrade |
Temperature rangeradius | 400℃ |
Temperature accuracyblade to jawand dust collector | ±0.2 ℃ |
Display resolution | 0.1℃ |
Maximum comsuption | < 600W |
Temperature recovery time | less than 4 min. |
Weight parameters | |
Weight accuracy | ±0.5% |
Basic configuration | 0.325kg, 1.kg, 2.1kg, 3.kg, 5.kg, 10.0kg, 12.kg, 21.6kg |
Position detection | |
Loop distance from up and down | 30mm |
Control precision | ± 0.1mm |
Test flow control | |
Times of cutting the material | 0~10 times |
Material cutting interval | 0~999s(set reference Table 2) |
Control flow reaches the set temperature without volatility | |
Barrel temperature time | 15 min. |
Material be installed | 1 min |
Material sample temperature recovery time | 4 min. |
When binder set | 1min |
Melt Flow Index Tester
Description:
Melt flow index tester for ABS, polystyrene, polyethylene, polypropylene, polyamide, fiber resin, acrylate, POM, fluoroplastic, polycarbonate and other plastic materials, melt flow rate (MFR) or Melt volume flow (MVR) is to be determined.
Standards:
GB/T3682-2000,ISO1133-97, ASTM1238,ASTM D 3364,DIN 53735,UNI-5640,JJB878 ect.
Characteristics:
1. Fast heating speed, very small overshoot.
2. High precision of constant temperature.
3. Can accelerate recover to constant temperature condition after padding.
4. Can use manual and automatic material trimming test method.
5. LCD display, equipment with built-in micro printer, test result can be printed autocratically.
Specification:
Machine size(W*H*D) | 250*510*350mm |
Power | AC220V±10% 50/60HZ |
Barrel parameters | Inner hole 9.55±0.025mm |
Pistons parameters | Piston head: 9.475±0.015mm |
Piston length | H=6.35±0.1mm |
Paramters | Extrusion hole 1=2.095±0.005mm |
Temperature parameter | With intelligent temperature control instrument, with four pairs of significant temperature setting control, PID parameters can be automatically set, precision up to ± 0.1 degree centigrade |
Temperature rangeradius | 400℃ |
Temperature accuracyblade to jawand dust collector | ±0.2 ℃ |
Display resolution | 0.1℃ |
Maximum comsuption | < 600W |
Temperature recovery time | less than 4 min. |
Weight parameters | |
Weight accuracy | ±0.5% |
Basic configuration | 0.325kg, 1.kg, 2.1kg, 3.kg, 5.kg, 10.0kg, 12.kg, 21.6kg |
Position detection | |
Loop distance from up and down | 30mm |
Control precision | ± 0.1mm |
Test flow control | |
Times of cutting the material | 0~10 times |
Material cutting interval | 0~999s(set reference Table 2) |
Control flow reaches the set temperature without volatility | |
Barrel temperature time | 15 min. |
Material be installed | 1 min |
Material sample temperature recovery time | 4 min. |
When binder set | 1min |